… HPD The base device tree configures the edp_hot_plug_det pin using the "edp_hot" function on GPIO 60. However, on qcs6490-rb3gen2 this external HPD GPIO does not generate a connect event when a display is already connected at boot, causing the DP/eDP display to remain disabled. The DP controller’s native HPD correctly detects the connected sink in this scenario, so continue using the DP controller native HPD on the qcs6490-rb3gen2 platform instead of the external HPD GPIO. Link: https://lore.kernel.org/all/20260228-edp_hpd_rb3_gen2_for_next-v1-1-aebc047eddc1@oss.qualcomm.com/ Signed-off-by: Vishnu Saini <vishnu.saini@oss.qualcomm.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The base device tree configures the edp_hot_plug_det pin using the
"edp_hot" function on GPIO 60. However, on qcs6490-rb3gen2 this external
HPD GPIO does not generate a connect event when a display is already
connected at boot, causing the DP/eDP display to remain disabled.
The DP controller’s native HPD correctly detects the connected sink
in this scenario, so continue using the DP controller native HPD
on the qcs6490-rb3gen2 platform instead of the external HPD GPIO.